本年度的CIC也曾搞了一个多月,按照东京备忘录公布的音信,从9月1日至10月1日共淹留117艘船舶。
一般情况,东京备忘录淹留船舶月均在100艘傍边,这样看并莫得大幅度普及,这与老编的权衡有所差距,诸君船东不错略微减轻警惕,固然搞不解白出现这种情况的背后逻辑,但但愿接续保握这个低迷的景色……
英雄联盟投注
图片
ag官方有一又友留言思知谈,最近PSCO开具的劣势有哪些,老编蚁合了能蚁合到的悉数内容,整理如下,以飨诸君老铁。图片
01消防演习永诀格淹留劣势1.The crew were unable to perform a satisfactory fire drill. when simulate engine room fire, the engine room vent was not closed and fire-fighter's outfit dress non-standard, the lifeline was not connected during fire fighter enter engine room.
模拟机舱火灾的消防演习永诀格,具体永诀格的发扬是:机舱没磋议闭风机,船员穿消防服不利索,消防员插足机舱后,消防绳莫得固定在一个得当的位置。
图片
皇冠客服飞机:@seo36872.Fire drill for galley room be witnessed by PSCO and found to be not satisfactory——not starting fire pump, non two jets of water, not checking operation of fire damper and ventilation in drill area, not checking arrangements for ship abandon and no rescue team with stretcher(厨房模拟消防演习永诀格,具体永诀格发扬是:莫得开动消防泵,莫得准备两个皮龙,莫得查验演习区域风机,莫得查验弃船干系开垦,辅助队莫得带担架)
图片
3.During E/R fire drill, after fire alarm, crew members directly muster in E/R, not reportting to muster station, fireman wearing fireman’s outfit in E/R, and other crew members also standing in E/R which is fire scene without wearing fireman’s outfit, crew members can not carry out fire drill according to muster list. fire drill not satisfactory. (机舱模拟消防演习,消防警报响起后,船员没用在救急衔尾地点衔尾,而是平直在机舱衔尾,探火员穿上消防服之后,其他船员依然在机舱恭候,船员不知谈应变部署表上我方应该实行的任务)
4.During fire drill found following deficiency: no fire detection before putting out the fire by water, no person close the ventilation of fire area. (消防演习本领,发现如下永诀格形貌:熄灭前没进行探火,没磋议闭着火区域透风系统)
5.One fireman’s protective clothing found broken. Fire drill carried out and found not satisfactory, fireman enter the fire scene with the SCBA low pressure alarm activated.(消防服陡立,消防演习永诀格,消防员呼吸器报警)
图片
以上消防演习是本年让船员头大的形貌
图片
02消防阻拦阀劣势1.The ventilation motor in independent generator engine not able to stop from outside.(发电机间的风机弗成从外部关闭。)
澳门银河线上赌博2.The three isolation valves for main fire line on main deck leaking. (消防系统,三个阻拦阀漏水)
3.Isolation valve for main fire line on deck severely rusted, some of them found inoperated.(消防系统阻拦阀锈蚀严重,弗成开关)
图片
03防火门劣势1.the emergency door release unit of bridge fire door malfunction.
从图片看是这个绿色的手动开释安设玻璃碎了,小劣势。
皇冠最新网址图片
2.the self-closing fire door that escape routes to open deck fastened with rope.
逃生通谈防火门被绑上了,这个简直绝顶日常绝顶多
和值分析:历史上066期,和值范围在53-148之间,和值平均值为97.00;去年同期前区奖号和值为111;本期关注和值下降54位,推荐和值在57左右。
前区龙头分析:最近20期中,龙头出现范围在1~9之间,近7期则是在2~9之间波动,在波动期间内出现最多的龙头是02,质合方面出现最多的是质数,共出现13次,本期精选龙头:07。
图片
3.The fire door for the ECR escape route was blocked from the ECR side that can not open from the other side.
集控室通往逃生通谈的门被锁住。
图片
网站以其优质的博彩服务和多样化的博彩游戏,让广大博彩爱好者能够在博彩游戏中获得更多的乐趣和收益,同时还提供最专业的博彩攻略和技巧分享,为用户提供最全面的博彩知识。4.The Air Balance Duct Of B-0 Class Fire Door For Room 405 Was Detached.
405房间,B-0级防火门透气窗被移除。
图片
5.The open direction of door on coaming deck corridor port side in escape routes is not in way of the direction of escape(coaming 船面,走廊右舷逃生通谈的门与逃生通谈的场所不一致)
图片
04消防水管干系1.fire hose on bridge deck found leaking seriously.
消防皮龙漏水,很常见。
图片
2.Main fire pipe near isolation valve on main deck found rusted and holed. (消防附近线上消防阻拦阀近邻管线锈蚀、洞穿)
图片
05风机干系1.The filter on control air pipeline for ventilation damper closing device leaking.
菠菜网最稳定正规平台机舱风机遥控关闭安设滤器处漏气。
图片
www.royalbetonlinezonehub.com2.Ventilator of bosun store room unable to be closed.(水手间风机无法关闭)
图片
06火灾探伤报警系统1.Fire alarm detection system fault on main pannel alarm.(火灾探伤报警系统适度面板浮现故障报警)
2.The alarm of the fire detection system is unable to be activated in the circumstance of more than three fire detectors in accommodation disconnection(PSCO让船员测试火灾探伤报警安设,测了三个探头,并莫得引发报警)
3.Audible and visal warning for the release of fixed co2 fire fighting system out of order (二氧化碳系统报警声光报警安设故障)
4.Two fire detectors in and outside air conditioner room malfunction when test(两个火灾报警探头故障)
皇冠足球比分網5.The audible alarm not sounded throughout the crew accommodation and service spaces when the fire alarm signals in E/R not received attention more than 2 mins(报警引发2min后,生计区依旧莫得报警声息)
图片
07其他1.The internal dimensions of the escape enclosure in engine room found less than 800mm*800mm (700mm*750mm) . (机舱逃生通谈内容为700mm*750mm,尺寸不恬逸800mm*800mm条目)
2.The fixed CO2 system discharge pipe for NO.6 C/H rusted seriously and holed at three position(6号货舱的固定式二氧化碳系统有三处锈穿和陡立)
以上是,暂时发现的淹留劣势实例银河娱乐股价大涨,更多CIC迎检手段点击传送门:2023年CIC,防PSCO淹留,全面迎检,终极无码篇!